Detroit, Michigan

The Detroit Metro Airport Blue Deck Parking Structure provides 5,500 parking spaces to patrons of the airport. The structure exhibited shear wall damage, failures with flange connectors and expansion joint systems, and premature deterioration of the tee surfaces, drainage basins, and numerous joint sealants. The extent of the damage was widespread.
Restoration Description
- Latex concrete overlay over 131,000 square feet with improved drainage profiles.
- Precast tee to tee shear transfer connection restoration.
- Expansion joint refitting including transfer beams.
- New floor drains.
- Shear wall reconnection and strengthening.